how to change fan speed on a trane furnace

You will also see the red E icon under Emergency . the module must be a trane furnace model specific programmed and is available separate from the motor. The problem is, the furnace control module doesn't use a separate speed when the unit is running in continuous FAN mode. On the motor, only one of the 5 numbered taps has 24v power at a time based on the speed desired at the control board. The control board is communicating with the blower module in order to determine the airflow volume needed. The company offers a variety of furnaces to suits the needs of every home. Heating, Cooling, Air Conditioning, Ventilation and T-Stat Controls, 3-Speed, 4-Wire Ceiling Fan Switch Wiring. However, a higher MERV rating may not be best for your system. Is it suspicious or odd to stand by the gate of a GA airport watching the planes? Inventor with two patents (weight training – anti-rollback for manual wheelchair) Its not advisable to slow your furnace blower speed. If the blower motor hums, check the blower fan to ensure that it spins freely. how to change fan speed on furnace to get more heat from your unit HVAC STARTUP TECHNICIAN 4.6K views 1 year ago Trane XV80 or XC80 Variable Speed Motor Blower Fan Not Working - $9. So I continued to play around with different combinations tonight. Measured the temperature of the air before the coil and after the coil and used DeltaT (change in temperature) to determine the blower setting. -The BTU/HR size is selectable between 48,000 42,000 36,000 or 30,000 BTU/HR. In this case, to adjust the blower speeds, move the dip switches (in the red section of the control board) to the positions shown in the manufacturer's installation instructions. That is incorrect. These three are connected to the "Cool", "Heat", and "Fan" terminals on the control board. Recently I did a blower speed adjustment on the 2nd floor air. Check out www.acservicetech.com/store. This can be done through an independent dehumidistat or through a thermostat's DEHUM terminal (if available). I'm not in enhanced mode. The control board has relays that regulate the voltage to each component in the furnace. Its a common occurrence in the heat of the summer or the cold of the winter one room doesnt get as warm or as cool as the others. I'd like to get some second opinions. By rejecting non-essential cookies, Reddit may still use certain cookies to ensure the proper functionality of our platform. I'm also going to go through and make sure there are no visible leaks or damage to them. This lower blower speed enhances To learn more, see our tips on writing great answers. Your OP was a noise complaint. The constant air turn over at a lower set point keeps the house comfortable. ECM blower motors do not require an external capacitor to operate. The most important factor is temperature differential - the difference between the inside temperature and outside temperature. I assume you are speaking about dip switch settings. I think that when it is in enhanced mode the fan only runs at 50%, you can try changing your dip switches to see. http://www.inspectorsjournal.com/Forum/topic.asp?TOPIC_ID=8998&, We've added a "Necessary cookies only" option to the cookie consent popup. Using a hammer, lightly tap out the blower motor shaft (fig.6.7) to loosen the blower motor from the fan shroud (fig.6.8). you will get the better dehumidification with the lower setting. Test your knowledge with our 1,000 question workbook along with the answer key! I've already had a few HVAC vendors give me some specious arguments about moisture buildup, another even told me he'd "lose his license" if he touched the job. By pressing "submit", I understand that I am providing express consent for Trane Residential to contact me about this request or similar topics. You will need to look at what the programmed speed designations are for M1/M2/M3/M4/M5 on the wiring diagram of the HVAC unit. The installation instructions for this furnace are needed in order to be able to know how to set these dip switches. This is NOT a user servicable item. The fan speed is very low when not heating/cooling. Home House & Components Systems Heating & Cooling System Air Conditioners. bean. rev2023.3.3.43278. Any takers? I needed to go the opposite direction and increase fan speed. The remaining colored wires are the speed selectors for this blower motor.). CFM stands for "cubic feet per minute." Iappreciate all the comments, questions, and responses that Ireceive from each of you. If you really wanted to be scientific, you could perform an experiment and post the results here. Click On under Emergency Heat. This value is then multiplied by 150 cfm to obtain the required airflow for the furnace in heating operation. Certified Welder One of these wires will be coming from the thermostat and the other will go to the outside unit. He is experienced in wood and metal construction, having designed and built several houses and metal buildings. If the furnace manufacturer supplies different burners for that unit you may be risking premature failure. In terms of heat pumps, running the external blower faster may reduce i2r copper losses and hysteresis iron eddy current losses. He is also an HVACR Contracting Business owner of 16 years and holds an NJ HVACR Master License. A slim, removable cover will reveal the filter location. Narrowing that hysteresis loop will: Leading to a smaller Hysteresis loop, increasing motor efficiency by reducing iron eddy current losses. If you are having problems, find your fans users manual and use it as a guide. I have also measured that on low speed my furnace requires AT-LEAST 1 hour of constant running to raise my home temp by 6 deg F. On high speed it takes 30-40 min. As a side note, lowering furnace (heating) blower speed should apparently only be done if it doesn't reduce the "heat rise" (difference in temperature between the intake and supply air, if I understand it, also known as the "delta T") past the manufacturer recommended value for that furnace. Identify those arcade games from a 1983 Brazilian music video. Why is there a voltage on my HDMI and coaxial cables? Its time to clear the air. With heating oil at $4.50/gal I can assure you without measuring anything that running my blower on low is NOT more efficient from a $$ perspective. If you do, you may not have enough air flow over the heat exchanger, resulting in overheating and eventually a shorter exchanger life span. Your AC or furnace is designed for a specific type of filter. HVAC filters help remove dust, dander, and harmful particles from the air inside your home. Access the control board. In order for the filter to work properly, the right size is crucial. The blower fan on this blower has four speeds. The blower energy draw at a lower speed will be offset by the loss in fan wheel inertia. Put the air handler back. Press Apply to save and exit. Connect the ohm meter to the pressure switch. Where To Find R-22 & R410A Leaks on AC Units! The automatic feature rarely kicks in once at set point. View our Privacy Policy here. I simply am unable to put my hands on the schematic. There is another way to wire this, but I can not find it back.. I found one glued to the back of my furnace door, one in the manual, and maybe one on-line too. For more information, please see our We are no longer supporting IE (Internet Explorer) as we strive to provide site experiences for browsers that support new web standards and security practices. Top Ten Interview Tips to Land that HVAC/R Job! Asking for help, clarification, or responding to other answers. In support of this: I found the mfr owner's manual for my furnace and in it, it states, "if you have an air-conditioning coil installed, you should switch the furnace blower speed to high to accommodate the decreased air-flow caused by the cooling coil in the plenum.". (FYI Filter was clean and furnace was recently serviced all prior to my initial investigation of the short cycling). H.R. The blower speed for a gas heater is selected so that it is comfortable for the building occupant but also so that the Delta T (Temp Rise) does not continue to rise. Air filters are measured by Minimum Efficiency Reporting Values (MERV). A properly fitted filter can also trap unwanted, and oftentimes unseen, pollutants from the air in your home, including: Start with the return vent. There is no humidistat. Learn more about Stack Overflow the company, and our products. Here's hoping for some good answers. Thoroughly rinse the filter. ECM Multi-Speed Blower Motor (Broad Ocean Type), For an ECM blower motor with wires exiting the module (shown above), the speed is changed at the control board by moving the colored wire terminals. Other than removing the module and seeing burnt components it must be diagnosed by a professional with a techmate tool ( allows you to test the motor and module and determine cause of error). To begin, turn off the power to your furnace. If the relay that controls the blower motor fails while it is closed, it will send continuous voltage to the blower motor, causing the motor to run continuously. How exactly could I test this? Does Nest utilize all the benefits of a communicating furnace, Low speed furnace fan blower motor will not shut off, How to calculate efficiency of old Westinghouse furnace VS new variable speed Furnace. Now that its gotten cold, we've noticed that several of the heat register barely have any air coming out of them. On this control board, there are multiple adjustments for the airflow speeds. Also related, with for instance a variable speed furnace, since it runs continuously and reduces "cold spots" you might find you can set it at a lower degree setting than the off/on kind. New XV80 Trane furnace makes noise when blower runs at low speed. How to Lower the Ouptut of Oversized Furnace. That said the contractor has no real incentive to get it right. Most of these are on the bottom left of the control board. Craig is a licensed Teacher of HVACR, Sheet Metal, and Building Maintenance in the State of New Jersey of the USA. This means that any time cooling is called for by the control board, 24v will be present on the #4 terminal of the motor module to turn the motor on and to run at roughly 1200 CFM. Follow us on Facebook for Quick Tips and Updates here! When the system calls for heat and the inducer fan begins to run, check each pressure switch terminal. Usually there will be three speeds ranging from 40 to 100% of airflow. Design Engineer/Project Manager for injection molded plastic company By clicking '. Carefully disconnect the wires from the coolant terminal, which is located on the back of the unit. In this HVAC training article, we will be discussing how to adjust the fan speeds on an indoor ECM variable speed blower motor and an ECM constant torque/multi-speed blower motor. One of these wires will be coming from the thermostat and the other will go to the outside unit. On this motor module, the speed wires are red, orange, blue, yellow, and black. Cockroaches and waterbugs coming in through the vents was my big clue there. (Variable & Multi-Speed Types), In this HVAC training article, we will be discussing how to adjust the fan speeds on an indoor, In order to measure air flow you could use a flow capture hood, a rotating vane anemometer, or a, I hope this helps you understand how to adjust the airflow speed on ECM Blower Motors! I understand the reason for slowing the air to remove humidity. It only takes a minute to sign up. Invention prototypes are another of his many accomplishments. video below! This BTU/HR capacity should be used to set the CFM for the indoor blower motor. We recommend our users to update the browser. It is about 1300-1400 sq feet, but then the basement was finished at some point, more or less doubling the square footage. During the awake hours I Hold the fan speed at either low or medium. Shay Tilander is a senior editor at Family Handyman. He farmed commercial garden produce for several years. Only swap these two wires. The heat exchanger can be overheated and burned out if the blower does not remove enough heat. Air Filters remove dust, lint, pet dander, and other pollutants so you can breathe easier knowing your indoor air quality is better with Trane. The arrow should face the direction the air is flowing. If it goes out of spec then on "very cold days" (when the furnace runs a lot) it could trigger an automatic shut off when the exchanger doesn't end up getting cooled enough, FWIW. Questions of a Do It Yourself nature should be 10 Reasons a Blower Fan Won't Start in a Furnace, AC or Heat Pump. You may freely link to this site, and use it for non-commercial use subject to our terms of use. I'm also a little concerned that this furnace might be a little undersized for our house (if I understand correctly, its a 100 BTU unit). Running your furnace fan all the time isn't exactly a bad thing. Thanks for the reply. Be sure to check out our previous article on ", If you want to learn about refrigerants and how they work in a system, check out our. (new Image()).src = 'https://capi.connatix.com/tr/si?token=2ba02a33-c319-4410-bba7-f8321a13bed3&cid=877050e7-52c9-4c33-a20b-d8301a08f96d'; cnxps.cmd.push(function () { cnxps({ playerId: "2ba02a33-c319-4410-bba7-f8321a13bed3" }).render("00499ba9282e4d1b985fa8af14d29c2b"); }); On my furnace IFC, the black (high speed) wire is connected to the air conditioning (cool) terminal, and yellow (medium-high speed) is connected to the (heat) terminal. These are not switched off but are live all the time. If a clear distinction between the blower speeds isn't obvious in the data, then you're probably not going to save much money either way, so go with what's most comfortable for you. This will help prevent injury and damage to the furnace fan. The house has a 3 ton trane xl20i and an xv80 (4 ton max). - The "Continuous Fan" refers to when the G terminal is powered for the fan only to run. Heat exchange takes time. After understanding what speed each tap is programmed for, we can make proper airflow adjustments. This will help prevent injury and. The wire's color will determine the speed settings that the motor will run at. Thanks for contributing an answer to Home Improvement Stack Exchange! A second filter location for most HVAC systems and furnaces is the air handler portion of the system. A 1.5 ton AC unit may not be large enough to cool the . Cut the wire's terminal connector off with wire cutters. Select Climate from the blue menu on the left side of the page. Identify the blower fan and the speed wires. Why is my furnace blower running at low speed? Changing the fan wire connection between the fan-on relay and the fan motor, selecting a high, medium, or low speed right on the fan motor itself Changing jumper positions on the control board (printed circuit board shown below) in the air handler Changing a dip switch or small slider switch position provided on some air handler control boards I was reading the Trane XL824 thermostat installation and setup manual. You can change the settings for cfm fan speed, but you have to do it manually at the board. For business related inquires email us at info@acservicetech.com. Connect with our Customer Care team about your products, warranties, and dealer concerns. When the summer air conditioning season transitions to the fall heating season, increase the blower speed by switching the wires on the cool and heat terminals. Then, carefully switch it to the setting of your choice and push it back into the control board. A continuous green light means the IFC circuit board needs replacing. If 1600 CFM is too high of an airflow volume and only 1200 CFM is needed because the system is a 36,000 BTU/HR air conditioner, we can swap the yellow with the black wire on the motor module. You need to follow the wiring diagram inside the HVAC unit. home improvement and repair website. Yes: you will save electricity costs by running your blower on low. If the ohm meter comes back with an open line reading, the switch is bad and needs replaced. The remaining colored wires will be default speeds. Sometimes you have to add more ducts to achieve the proper pressure and velocity. -The "AUX Heat" makes sure that there is enough airflow when elect strip heat is called. So if you are actually moving 1250 CFM then you are at 357 CFM/ton, which is a good setup for dehumidifying. The same is true when changing the air duct filter. AC Service Tech HVAC Training is made possible by continued support from our visitors, customers, and support from these Sponsors! Use tab to navigate through the menu items. Stage 2 Aux Heating. But you will have a tough time measuring either on your basement Trane. DoItYourself.com, founded in 1995, is the leading independent home improvement and repair website. In other units, it may be 2, 3, and 4 that are programmed. Not every AC or furnace filter will have an arrow printed on the frame, but when it does the arrow indicates the direction the filter must face. Remember that a heat pump in heating mode will need to run with roughly the same airflow speed as during AC mode even though it may not be comfortable for the building occupant. This will increase the number. with a wiring harness for the fan. The main difference is that the fan ON setting means that the fan is set to run as long as the furnace is switched ON. XB Trane Furnace: Is there a fan speed control on the unit. So How Do We Adjust Fan Speed? According to the manufacturer's documentation, your furnace should have a 3 or 4 speed blower motor. Turn off power at the main electric panel. Solution: Install a new sequencer AND a new fan relay, just to be safe. This video is to show how you can figure out the blower speed setup in your HVAC system, and what you can do do adjust said speeds. homininet 8 mo. By regularly changing your filter, you can improve your indoor air quality and extend the life of your heating and cooling system. Black: High; Yellow: Medium-high ; Blue or brown: Medium-low; Red: Low; Trane s9v2 should thermostat control blower speed? Yes--the efficiency of the heat exchanger will decrease. One fan is inside the house, and one is outside the home. Remove the air handler. For business related inquires email us at. Is it Covered Under Homeowners Insurance or a Home Warranty? Remove two screws from each bracket leg holding the motor. If you have a plug instead (ECM Broad Ocean) you can only make the adjustment at the control board or at the plug terminals at the end of the wiring. Upon initial installation, these dip switches need to be adjusted for the particular unit, size, and application. During the awake hours I Hold the fan speed at either low or medium. 3.5 x 400 = 1400 CFM. When one of the taps is powered with 24v, the motor will turn on and run at the selected speed. Especially with a high efficiency furnace, however, it may be that the decreased electric bill saves enough to offset the "loss up the flue" not sure. The arrow should point toward the unit. Trane. Proper duct sizing can resolve the issue you are having. Adjust the fan speed, and if you're still experiencing problems, contact your local American Standard Customer Care dealer. If you want to learn about refrigerants and how they work in a system, check out our Refrigerant Charging and Service Procedures for Air Conditioning book . Reddit and its partners use cookies and similar technologies to provide you with a better experience. The furnace operates for two minutes or so before it shuts down. On most control boards there will be a jumper that is marked to show that it controls the speed. Trane XR80 Troubleshooting After examining the flashing system you should check the green light speed. Air Filter - Be sure to check the air filter and replace if necessary. in this thread in this sub-forum in the entire site. The S8X1 blower has 9 speeds. No need for direct trane replacment motor. enjoys making jams and jellies during fruit season along with cooking meals. A MERV rating speaks to the filters ability to capture large particles. The installation guide clearly describes how to set airflow for heating mode and cooling mode. Mine. Motor is an ECM and it makes a low pitched whine sound when in CIRC or when the blower is ramping up or slowing down to stop. In the pictured example above, if the #5 speed tap is programmed for 1600 CFM and #4 is programmed for 1200 CFM and #5 is presently connected to the "Cool" terminal on the control board via the black wire, we know that the unit is running at around 1600 CFM as long as the TESP across the unit is not too high. When he's not enjoying family time with his wife and three boys, he loves tinkering with projects and geeking out on electronics. Click System Options. Locate your thermostat on the page and click System Mode. The best answers are voted up and rise to the top, Not the answer you're looking for? Should I upgrade to a pcm br compatible thermostat? Proper returns are rarely a thought. Dave. In order to determine or change the speed, check the wiring diagram of the furnace/air handler/package unit that the motor is installed in. It helps to have over 50 years of farming and ranching experience. They have a built in or attached capacitor that will allow the motor to turn on, turn off and run at a constant speed when running. If the blower motor is burned out, replace it. On the furnace / air handler board you should have two wires on the "Y2" connection, assuming a two-stage cooling system. So the blower motor is dead. Adjusting the Airflow Speed on ECM Blower Fan Motors! However, if your HVAC blower motor isn't too badly damaged, the technician may be able to clean and repair it so you won't have to incur the cost of a replacement. (Without enclosing my house in a climate-controlled bubble). It wasn't the noise that was bothering me, it was the desert-like sensation of swirling dry air. It is a Trane S8X1 single stage furnace and air handler, paired with an XR16 3 ton AC unit. Typically the colors are: White = neutral speed Red = low speed Yellow = medium speed Black = high speed Various advertisements for variable speed high efficiency furnaces call them "more energy efficiency" (note also the difference between a variable speed blower and a high efficiency furnace, they're separate, for instance you can have a variable speed blower on a low efficiency furnace). Locate the speed wires. @Dave: Those were my thoughts as well. View our Privacy Policy here. We have been heating the crawl space in our house for several winters because the ductwork was all torn up from rats. Now, I haven't done the measurement to learn how much electricity my blower uses on low vs high. I'll edit my answer and include the exact parameters I'd record every day for a thorough study. These blower motor versions can be found in furnaces, air handlers, and packaged units. 1995-2023 MH Sub I, LLC dba Internet Brands. Has anyone done this and can anyone give me a reason why I shouldn't do this? The manual document include instructions and informations on how to troubleshoot the system. Published: 05/19/2021 Author: Craig Migliaccio, About the Author: Craig is the owner of AC Service Tech LLC and the Author of the book Refrigerant Charging and Service Procedures for Air Conditioning. How do I check if this furnace switch the blower to second speed. Home Improvement Stack Exchange is a question and answer site for contractors and serious DIYers. charts are usually found on the air handler inside door to controls. If you want to solve the air noise problem, move the return air filters out of their hallway locations back to the upstream side of the return air duct at the furnace. (Heat transfer wasn't one of my favorite classes in college - I focused more on dynamic systems, sorry.). If the instructions are not with the furnace, you can look up the model number of the unit and search for the installation manual via a google search. The ohm meter should read very close to zero. I have a Trane XV90 propane furnace with a variable speed blower. One thing I found consistently was that making changes on the RS-485 hydro heat control board and W1-W3 jumpering had notable effects (more CFM's at my test register) while messing with the mainboard DIP switches had little to no effect. -The "AC/HP CFM Adjust" is the airflow volume to be set for system, efficiency, comfort. Since I first posted this thread, my installer called Trane to get an answer to my original question. Another common place with a schematic is on the back of the blower fan door. By clicking Post Your Answer, you agree to our terms of service, privacy policy and cookie policy. This will show what speed each numbered tap is programmed as. Related: a two stage furnace works by actually shooting less gas out, which might improve its efficiency. If the control board is at fault, replace it. Allow the filter to completely dry before returning it to the device. Here are common Trane AC repairs not listed in the guide and their repair cost for parts and labor: Leaking coil and refrigerant: $1,150-$1,750 Thermostatic expansion valve (TXV): $275-$450 Compressor and refrigerant (after ten years, typically): $1,150-$1,600 Failed solder connection on refrigerant lines and refrigerant: $875-$1,220 The hot air will rise and heat the floor from beneath, a DIY form of radiant floor heating. A 90 percent-plus furnace needs 150 cfm per 10,000 Btu of input. During "Fan On", the fan runs at 50% of whatever the maximum speed of the fan is. 1 to 1.5 hours | Install the new motor, adjust it (multispeed and variable speed blowers only), run and test the furnace Installing a blower wheel with the motor shouldn't affect installation time, since the old wheel typically has to be removed to replace the motor. It had been set on the higher speed, but that was too harsh, so I lowered it to the slower speed. Thanks for all your continued support! Available from Trane Dealers in select locations. 80% would be great for me. I want to increase volume flow if possible. Typical setups include these wire colors with associated blower speeds. I know I need to replace a dying blower motor in a 1992 Trane . Wires from the 16 pin plug are connected to this board. However, during the time period while the compressor is not engaged I need to circulate more air on the second floor or it becomes stale. Here are how my dip switches are set: Did the installer tie in a humidistat there on that V/S blower . Does lowering the blower speed of a forced-air furnace lower its efficiency? A description of how to change motor speeds with a multiple speed fan motor on an IFC controlled furnace.This video is part of the heating and cooling series of training videos made to accompany my websites: www.graycoolingman.com and www.grayfurnaceman.com to pass on what I have learned in many years of service and repair. BS in Industrial Technology, If you know what you are doing, it is very simple to adjust the speed of, Before you begin this process it is a good idea to make sure that no power is going to the fan. For 240v units, both the L and N are hots. This is done so that the maximum amount of heat is gained in the building from the refrigerant. You could also use the Temp Rise Formula which you can learn about in our "HVAC Temp Rise Formula used to Measure Airflow CFM" video. Switch the Jumper On most control boards there will be a jumper that is marked to show that it controls the speed. Stack Exchange network consists of 181 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers.

Ethan And Casey Jones Net Worth, Palm Sunday Palm Leaf Crafts, Martin Lewis Advice On Funeral Plans, Which Part Of The Chromatogram Represents The Asn Oligomers, Articles H